Work Order 360 View
Detailed work order timeline, KPIs, and analysis
PC
Per client agreement
Target:
Nov 20, 2025
🕐 Clock stopped: Completed (Nov 23)
✗ SLA Missed (2d late)
Coordinators
12.8 days
Over SLA
Field Work
15.0 days
Over SLA
Billing
1.5 days
Over SLA
Created: Nov 6, 2025
Due: Nov 20, 2025
Completed: Dec 12, 2025 (21 days late)
⏱️
15.0d in Completed
Longest Stage
🔄
8 transitions
Status Changes
⚠️
25.8d over
Total Delay
📦
0 orders, 0 quotes
Parts & Quotes
AI Analysis
Powered by OpenAI
Generating AI analysis...
🎫
Case #00541679
URGENT Philips WO Request
Closed
🚨
Primary Delay
15.0 days stuck in "Completed"
⏱️
Total Delay
25.8 business days over SLA thresholds
SLA vs Actual Time by Status
Ready for Scheduling
0.0d
/ 1.0d SLA
Assigned
11.8d
/ 0.5d SLA
Scheduled
0.9d
/ 2.0d SLA
Completed
15.0d
/ 1.0d SLA
Ready to Bill
1.5d
/ 1.0d SLA
💬 Activities, Notes & Communications
📝 WO Notes (6)
💬 Chatter (1)
📅 Events (1)
📧 Case Activity (1)
🔒
Internal CSA Notes
11/06/2025 Cever assigning to FSE to get quotes and po
🔧
Work Performed
The FSE installed a new RP-Trilogy Evo 3 Way Solenoid Valve and RP-Trilogy Evo Proportional Valve (AECM), Performed a complete PVT as per the MFG's specifications. All tests and calibrations were found to be in spec or passed tests.Device placed back into full clinical service; ready for patient use.
🔍
Technician Findings
Repair.
⚠️
Problem Description
Upon initial inspection of the device, A pre‑existing fault was detected: the device failed the Active Exhalation Verification in the System Setup Test. This must be resolved before proceeding with FCO86600081 implementation.
📄
Description
Philips Trilogy EV300 Hospital Ventilator (DS2200X11B / 989805661881)
📞
Call Description
Repair - Trade
Nov 6, 2025 12:10pm
Hi, @Rebecca Arnold. This is the work order number requested per the below. Thanks!
Repair - Trade
WO-13851229
Serial Number:H353495170AB0
Local POC Name (Secondary): Rebecca Arnold
Healthalliance Hospital
105 Marys Ave
Kingston, NY 12401
📅
WO-01313478 - Repair - Trilogy EV300 Vent - Kingston - Healthalliance Hospital
Nov 21, 2025 8:00am – 5:00pm
Work Order: WO-01313478
Account: PHILIPS HEALTHCARE
Customer Case Number: WO-13851229
Location: Healthalliance Hospital
Address: 105 Marys Ave, Kingston, NY 12401
Manufacturer: Philips Healthcare
Model #: Trilogy EV300 Vent
Serial #: H353495170AB0
Contact Name: Kevin Blom
Contact Phone: (845) 705-30
Case #00541679 – URGENT Philips WO Request
Status: Closed | Priority: High
💬
Case Comment
Internal
Nov 6, 2025 12:10pm
11/06/2025 JRolston - Created EWO-01313478 accordingly.
Timeline
📞
Case Number:
00541679
Subject:
URGENT Philips WO Request
Status:
Closed
📋
📅
From:
Entered
To:
Ready for Scheduling
Duration in Previous:
2m
📅
🗓️
From:
Assigned
To:
Scheduled
Duration in Previous:
14d 23h
📅
Scheduled For:
2025-11-21T13:00:00.000+0000
⏱️
✔️
From:
Scheduled
To:
Completed
Duration in Previous:
2d 6h
🚗
Type:
Travel
Status:
Open
Qty:
130
🏁
From:
Completed
To:
Closed
Duration in Previous:
20d 15h
⏱️
📋
From:
Closed
To:
07e-Partial Project
Duration in Previous:
1d 2h
📄
From:
07e-Partial Project
To:
Ready to Bill
Duration in Previous:
3d 3h
💰
From:
Ready to Bill
To:
Invoiced
Duration in Previous:
12h 49m
Bottlenecks
Assigned
Duration: 11.8 business days (threshold: 4.0 business hours)
Exceeded by 11.3 business days
Completed
Duration: 15.0 business days (threshold: 1.0 business days)
Exceeded by 14.0 business days
Ready to Bill
Duration: 1.5 business days (threshold: 1.0 business days)
Exceeded by 3.8 business hours
ℹ️ Work Order Details
Scheduled
Nov 21, 8:00 AM
Work Details (4)
Name
Type
Status
Qty
Amount
Date
WL-03017791
Labor
Open
3
$155.00
Nov 23, 5:53 PM
WL-03017792
Labor
Open
1.5
$142.50
Nov 23, 5:53 PM
WL-03017794
Travel
Open
130
$0.00
Nov 23, 5:58 PM
WL-03037866
Labor
Open
0.016666666666667
$38.00
Dec 15, 11:43 AM