Work Order 360 View
Detailed work order timeline, KPIs, and analysis
PC
Per client agreement
Target:
Dec 4, 2025
🕐 Clock stopped: Completed (Dec 23)
✗ SLA Missed (18d late)
Dispatch
0.9 days
Over SLA
Holding (excluded from total)
0.0 days
Coordinators
25.5 days
Over SLA
Billing
3.5 days
Over SLA
Created: Nov 18, 2025
Due: Dec 4, 2025
Completed: Dec 23, 2025 (18 days late)
⏱️
22.3d in Assigned
Longest Stage
🔄
7 transitions
Status Changes
⚠️
25.9d over
Total Delay
📦
0 orders, 0 quotes
Parts & Quotes
AI Analysis
Powered by OpenAI
Generating AI analysis...
🎫
Case #00544639
URGENT Philips WO Request
Closed
🚨
Primary Delay
22.3 days stuck in "Assigned"
⏱️
Total Delay
25.9 business days over SLA thresholds
SLA vs Actual Time by Status
Assigned
22.3d
/ 0.5d SLA
Scheduled
3.2d
/ 2.0d SLA
Ready to Bill
3.5d
/ 1.0d SLA
💬 Activities, Notes & Communications
📝 WO Notes (6)
📅 Events (1)
📧 Case Activity (1)
🔒
Internal CSA Notes
12/18/2025 RArnold- Dispatching to Fady k for 12/19
11/18/2025 RArnold - WO for device that failed FCO81. PWO Pending entitlement
🔧
Work Performed
The FSE installed a new RP-Trilogy Evo 3 Way Solenoid Valve and RP-Trilogy Evo Proportional Valve (AECM), Performed a complete PVT as per the MFG's specifications. All tests and calibrations were found to be in spec or passed tests.Device placed back into full clinical service; ready for patient use.
🔍
Technician Findings
Repair.
⚠️
Problem Description
Upon initial inspection of the device, A pre‑existing fault was detected: the device failed the Active Exhalation Verification in the System Setup Test. This must be resolved before proceeding with FCO86600081 implementation.
📄
Description
Philips Trilogy EV300 Hospital Ventilator (DS2200X11B / 989805661881)
📞
Call Description
Repair - Trade
📅
WO-01315885 - Repair - Trilogy EV300 Vent - Camden - Cooper Hospital
Dec 19, 2025 8:00am – 5:00pm
Work Order: WO-01315885
Account: PHILIPS HEALTHCARE
Customer Case Number: WO-13927716
Location: Cooper Hospital
Address: 1 Cooper Plz, Camden, NJ 08103
Manufacturer: Philips Healthcare
Model #: Trilogy EV300 Vent
Serial #: H2775086098F7
Contact Name: Michael Youch
Contact Phone: 856-693-0740
Contact
Case #00544639 – URGENT Philips WO Request
Status: Closed | Priority: High
💬
Case Comment
Internal
Nov 18, 2025 9:09am
11/18/2025 JRolston - Created EWO-01315885 accordingly.
Timeline
📞
Case Number:
00544639
Subject:
URGENT Philips WO Request
Status:
Closed
📋
Work Order:
WO-01315885
Type:
Repair
Priority:
PC
✅
👷
From:
Ready for Release
To:
Assigned
Duration in Previous:
1m
📅
🗓️
From:
Assigned
To:
Scheduled
Duration in Previous:
29d 17h
⏱️
✔️
From:
Scheduled, Completed
To:
Completed, Closed
Duration in Previous:
4d 10h, 0m
⏱️
Type:
Labor
Status:
Open
Qty:
0.016666666666667
📋
From:
Closed
To:
07e-Partial Project
Duration in Previous:
12h 31m
📄
From:
07e-Partial Project
To:
Ready to Bill
Duration in Previous:
5h 48m
💰
From:
Ready to Bill
To:
Invoiced
Duration in Previous:
2d 13h
Bottlenecks
Entered
Duration: 7.4 business hours (threshold: 4.0 business hours)
Exceeded by 3.4 business hours
Assigned
Duration: 22.3 business days (threshold: 4.0 business hours)
Exceeded by 21.8 business days
Scheduled
Duration: 3.2 business days (threshold: 2.0 business days)
Exceeded by 1.2 business days
Ready to Bill
Duration: 3.5 business days (threshold: 1.0 business days)
Exceeded by 2.5 business days
ℹ️ Work Order Details
Scheduled
Dec 19, 8:00 AM
Work Details (3)
Name
Type
Status
Qty
Amount
Date
WL-03045776
Labor
Open
1.5
$142.50
Dec 22, 8:29 PM
WL-03045777
Labor
Open
1
$155.00
Dec 22, 8:29 PM
WL-03046007
Labor
Open
0.016666666666667
$38.00
Dec 23, 8:55 AM