FMI 32097:- Inspection of heater door screws for Giraffe OmniBed and Giraffe OmniBed Carestation Purpose:- Certain Giraffe OmniBed and Giraffe OmniBed Carestation may have defective heater doors due to improper torquing of heater door screws. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at tcs.fmiadmins@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
SN TAB24230120SA
Primary Delay66.4 days stuck in "Ready for Release"
⏱️
Total Delay22.3 business days over SLA thresholds
SLA vs Actual Time by Status
Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
0.0d / 0.5d SLA
Ready for Scheduling
21.1d / 1.0d SLA
Ready for Release
66.4d
Scheduled
3.0d / 2.0d SLA
Completed
0.1d / 1.0d SLA
Closed
2.3d / 1.0d SLA
Ready to Bill
0.3d / 1.0d SLA
Invoice Pending
1.7d / 2.0d SLA
💬 Activities, Notes & Communications
🔒Internal CSA Notes
03/31/2026 mklose rcvd email from Sajin, confirm Thursday
03/31/2026 mklose rcvd email from Sajin, confirm device. offered Thursday or Friday
03/30/2026 mklose called 845-274-5053 spoke with Sajin. sent him email with serial numbers.
🔧Work Performed
Template Name: FMI32097_Code 1_inspect.
Template Description: FMI32097_Code 1_inspect.
Problem Found: FMI32097_Heater door inspection.
Action Taken: FMI 32097 completed. Inspected the Heater doors
and confirmed screws tightened to the specification.
Verification Test:
1. Verified the canopy moves smoothly.
2. Verified transition mode message is not present.
3. Verified doors close smoothly.
4. Verified corner pins are aligned.
5. Verified no alarms.
The device has passed all tests and is ready for customer
🔍Technician Findings
N/A
⚠️Problem Description
FMI 32097:- Inspection of heater door screws for Giraffe OmniBed and Giraffe OmniBed Carestation Purpose:- Certain Giraffe OmniBed and Giraffe OmniBed Carestation may have defective heater doors due to improper torquing of heater door screws. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at tcs.fmiadmins@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
SN TAB24230120SA
📄Description
GE Healthcare Giraffe OmniBed Carestation CS1
📞Call Description
FMI 32097
📞
Call
Completed Mar 30, 2026
03/30/2026 mklose called 845-274-5053 spoke with Sajin. sent him email with serial numbers.
Work Order: WO-01316649
Account: GE Healthcare FMI
Customer Case Number: 1-556558341869
Location: GOOD SAMARITAN HOSPITAL
Address: 255 LAFAYETTE AVE, SUFFERN, NY 10901
Manufacturer: GE Healthcare
Model #: Giraffe OmniBed Carestation
Serial #: TAB24230120SA
Contact Name: Sajin Thomas
Contact Phone: 8
JFIF
TAB24230120SA-SN
Apr 2, 2026
JFIF
TAB24230120SA-Right screw
Apr 2, 2026
JFIF
TAB24230120SA- Left screw
Apr 2, 2026
Timeline
📞
Case Linked Nov 20, 2:29 PM
Case Number:00545672
Subject:GE FMI 32097 - Good Samaritan
Status:Closed
📋
▶
2
Work Order Created Nov 21, 9:09 AM
Work Order Created → Status: Ready for Scheduling
📅
Status: Ready for Scheduling by Sherry Reich
From:Entered
To:Ready for Scheduling
Duration in Previous:3m
🚨21.0 business days
✅
Status: Ready for Release by Erin MartinDec 23, 3:28 PM
From:Ready for Scheduling
To:Ready for Release
Duration in Previous:32d 6h
🚨67.0 business days
📅
Status: Ready for Scheduling by Megan KloseMar 31, 9:30 AM