Work Order 360 View
Detailed work order timeline, KPIs, and analysis
PC
Per client agreement
Target:
Jan 30, 2026
🕐 Clock stopped: Completed (Dec 4)
✓ SLA Met (57d early)
Coordinators
4.3 days
Over SLA
Field Work
2.8 days
Over SLA
Billing
11.7 days
Over SLA
Created: Dec 1, 2025
Due: Jan 30, 2026
Completed: Dec 4, 2025 (57 days early)
⏱️
8.4d in Ready to Bill
Longest Stage
🔄
14 transitions
Status Changes
📦
0 orders, 0 quotes
Parts & Quotes
👤
Self-Scheduled
Scheduling
🚩
3 On-Site Visits
3 on-site visits — why were multiple trips needed?
👤 Self-scheduled by Jose Gutierrez — scheduling delays attributed to technician, not coordinators
Visit 1
Dec 2, 2025
Visit 2
Dec 3, 2025
Visit 3
Dec 4, 2025
AI Analysis
Powered by OpenAI
Generating AI analysis...
🎫
Case #00547544
6008245562
Closed
28U
SYS-LC-1260
Repair
WO81912378:BINARY PUMP LEAKING
🚨
Primary Delay
8.4 days stuck in "Ready to Bill"
⏱️
Total Delay
9.5 business days over SLA thresholds
SLA vs Actual Time by Status
Scheduled
3.0d
/ 2.0d SLA
Tech On Site
2.6d
/ 1.0d SLA
Tech Off Site
0.2d
/ 2.0d SLA
Ready to Bill
8.5d
/ 1.0d SLA
Billing Review
3.1d
/ 2.0d SLA
Invoice Pending
0.0d
/ 2.0d SLA
💬 Activities, Notes & Communications
📝 WO Notes (5)
📅 Events (1)
🔒
Internal CSA Notes
Please assign to Jose Gutierrez
ARP to site is 20 miles. Zone 1
🔧
Work Performed
Replaced pump damper, as it was found to be leaking while performing PM. During PM, found ALS loop to be
leaking and the recently replaced needle seat to be clogged. Replaced inlet tubing and MCGV after gradient
composition test failure while performing OQ. During troubleshooting, accidentally broke the capillary that goes
from TCC to VWD. After parts replacement, all tests passed. More information can be found on the EQP for CH1298.
⚠️
Problem Description
28U
SYS-LC-1260
Repair
WO81912378:BINARY PUMP LEAKING
📄
Description
1260 Quaternary Pump
📞
Call Description
Jan 2026 LC REPAIR
📅
WO-01317557 - Repair - G1311B - San Antonio - DPT LABORATORIES
Dec 2, 2025 10:00am – 1:00pm
Work Order: WO-01317557
Account: AGILENT TECHNOLOGIES (ASP)
Customer Case Number: 6008245562
Location: DPT LABORATORIES
Address: 3300 RESEARCH PLAZA, San Antonio, TX 78235
Manufacturer: Agilent Technologies
Model #: G1311B
Serial #: DEAB702419
Contact Name: Reid Streidl
Contact Phone: 2107188197
Con
Timeline
📞
📋
Work Order:
WO-01317557
Type:
Repair
Priority:
PC
📅
From:
Entered, Ready for Scheduling
To:
Ready for Scheduling, Assigned
Duration in Previous:
0m
👷
Technician:
Jose Gutierrez
🗓️
📅
Scheduled For:
2025-12-02T15:00:00.000+0000
🔧
From:
Scheduled
To:
Tech On Site
Duration in Previous:
12h 31m
🚗
From:
Tech On Site
To:
Tech Off Site
Duration in Previous:
7h 5m
⏱️
Type:
Labor, Travel
Status:
Open
Qty:
0.33333333333333, 4, 13
🔩
🗓️
From:
Tech Off Site
To:
Scheduled
Duration in Previous:
1h 58m
🔧
From:
Scheduled
To:
Tech On Site
Duration in Previous:
14h 7m
🚗
From:
Tech On Site, Tech Off Site
To:
Tech Off Site, Scheduled
Duration in Previous:
9h 31m, 0m
⏱️
Type:
Labor
Status:
Open
Qty:
0.5, 3
🚗
Type:
Travel
Status:
Open
Qty:
13
🔧
From:
Scheduled
To:
Tech On Site
Duration in Previous:
17h 15m
⏱️
Type:
Labor
Status:
Open
Qty:
0.5, 1, 0.33333333333333
🚗
Type:
Travel, Parts
Status:
Open
Qty:
13
✔️
From:
Tech On Site, Completed
To:
Completed, Closed
Duration in Previous:
5h 23m, 0m
🔩
📄
From:
Closed
To:
Ready to Bill
Duration in Previous:
22h 10m
💵
From:
Ready to Bill
To:
Billing Review
Duration in Previous:
12d 2h
📄
From:
Billing Review
To:
Ready to Bill
Duration in Previous:
4d 18h
📨
🧾
Invoice Number:
SM-249754
💰
From:
Invoice Pending
To:
Invoiced
Duration in Previous:
3m
Bottlenecks
Assigned
Duration: 1.3 business days (threshold: 4.0 business hours)
Exceeded by 6.8 business hours
Tech On Site
Duration: 1.0 business days (threshold: 1.0 business days)
Exceeded by 0.0 business hours
Closed
Duration: 1.2 business days (threshold: 1.0 business days)
Exceeded by 1.3 business hours
Ready to Bill
Duration: 8.4 business days (threshold: 1.0 business days)
Exceeded by 7.4 business days
Billing Review
Duration: 3.1 business days (threshold: 2.0 business days)
Exceeded by 1.1 business days
ℹ️ Work Order Details
Technician
Jose Gutierrez
Scheduled
Dec 2, 10:00 AM
Work Details (23)
Name
Type
Status
Qty
Amount
Date
WL-03024165
Labor
Open
0.33333333333333
$0.00
Dec 2, 6:52 PM
WL-03024166
Labor
Open
4
$456.00
Dec 2, 6:52 PM
WL-03024167
Labor
Open
0.33333333333333
$0.00
Dec 2, 6:52 PM
WL-03024168
Travel
Open
13
$180.00
Dec 2, 6:52 PM
WL-03024169
Travel
Open
13
$0.00
Dec 2, 6:52 PM
WL-03024237
Parts
Open
1
$0.00
Dec 2, 7:21 PM
WL-03024238
Parts
Open
1
$0.00
Dec 2, 7:21 PM
WL-03025676
Labor
Open
0.5
$0.00
Dec 3, 8:05 PM
WL-03025677
Labor
Open
3
$342.00
Dec 3, 8:05 PM
WL-03025678
Labor
Open
0.5
$0.00
Dec 3, 8:05 PM
WL-03025690
Travel
Open
13
$180.00
Dec 3, 8:16 PM
WL-03025691
Travel
Open
13
$0.00
Dec 3, 8:16 PM
WL-03026866
Labor
Open
0.5
$0.00
Dec 4, 5:27 PM
WL-03026867
Labor
Open
1
$114.00
Dec 4, 5:27 PM
WL-03026868
Labor
Open
0.33333333333333
$0.00
Dec 4, 5:27 PM
WL-03026906
Travel
Open
13
$180.00
Dec 4, 5:33 PM
WL-03026907
Travel
Open
13
$0.00
Dec 4, 5:33 PM
WL-03026908
Parts
Open
1
$0.00
Dec 4, 5:33 PM
WL-03026909
Parts
Open
1
$0.00
Dec 4, 5:33 PM
WL-03026910
Parts
Open
1
$0.00
Dec 4, 5:33 PM
WL-03026911
Parts
Open
1
$0.00
Dec 4, 5:33 PM
WL-03028325
Parts
Open
1
$0.00
Dec 5, 3:50 PM
WL-03028326
Parts
Open
1
$0.00
Dec 5, 3:50 PM