FMI 32097:- Inspection of heater door screws for Giraffe OmniBed and Giraffe OmniBed Carestation Purpose:- Certain Giraffe OmniBed and Giraffe OmniBed Carestation may have defective heater doors due to improper torquing of heater door screws. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at tcs.fmiadmins@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
Primary Delay52.5 days stuck in "Ready for Release"
⏱️
Total Delay23.0 business days over SLA thresholds
SLA vs Actual Time by Status
Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
0.0d / 0.5d SLA
Ready for Scheduling
8.6d / 1.0d SLA
Ready for Release
52.5d
Scheduled
7.4d / 2.0d SLA
Tech On Site
0.2d / 1.0d SLA
Completed
0.0d / 1.0d SLA
Closed
4.0d / 1.0d SLA
Ready to Bill
9.4d / 1.0d SLA
Billing Review
0.0d / 2.0d SLA
Invoice Pending
1.7d / 2.0d SLA
💬 Activities, Notes & Communications
🔒Internal CSA Notes
02/19/2026 MHamersley - while researching for reply to email: found email communications between Jeremy and Fady, dtd 02/09/2026, waiting for reply from Jeremy to confirm and schedule ... 01/02/2026 MHamersley - called 864-512-1403, spoke to Jeremy, he insisted that i wasn't supposed to call him directly and need to contact GE 1800 #; sent email: jeremy.tessier@gehealthcare.com
🔧Work Performed
Template Name: FMI32097_Code 1_inspect.
Template Description: FMI32097_Code 1_inspect.
Problem Found: FMI32097_Heater door inspection.
Action Taken: FMI 32097 completed. Inspected the Heater doors and confirmed screws tightened to the specification.
Verification Test:
1. Verified the canopy moves smoothly.
2. Verified transition mode message is not present.
3. Verified doors close smoothly.
4. Verified corner pins are aligned.
5. Verified no alarms.
The device has passed all tests and is ready for customer use.
🔍Technician Findings
FMI
⚠️Problem Description
FMI 32097:- Inspection of heater door screws for Giraffe OmniBed and Giraffe OmniBed Carestation Purpose:- Certain Giraffe OmniBed and Giraffe OmniBed Carestation may have defective heater doors due to improper torquing of heater door screws. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at tcs.fmiadmins@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
📄Description
GE Healthcare Giraffe OmniBed Carestation CS1
📞Call Description
FMI 32097
📅
WO-01325099 - FCO - DD: 4/27/2026 - - Giraffe OmniBed Carestation - ANDERSON - ANMED HEALTH
Mar 19, 2026 8:00pm – 8:00pm
Work Order: WO-01325099
Account: GE Healthcare FMI
Customer Case Number: 1-556722374537
Location: ANMED HEALTH
Address: 800 N FANT ST, ANDERSON, SC 29624-3415
Manufacturer: GE Healthcare
Model #: Giraffe OmniBed Carestation
Serial #: TAB23120012SA
Contact Name: Jeremy Tessier
Contact Phone: 864) 512
JPG
TAB23120012SA_SCREWS
Mar 20, 2026
JPG
TAB23120012SA_HOOD
Mar 20, 2026
JPG
TAB23120012SA_SN
Mar 20, 2026
Timeline
📞
Case Linked Dec 11, 1:57 PM
Case Number:00551026
Subject:GE FMI 32097 - Anmed
Status:Closed
📋
▶
2
Work Order Created Dec 11, 2:14 PM
Work Order Created → Status: Ready for Scheduling
📅
Status: Ready for Scheduling by Shelby Robinson
From:Entered
To:Ready for Scheduling
Duration in Previous:0m
⚠️9.0 business days
✅
Status: Ready for Release by Erin MartinDec 23, 3:20 PM