Midmark Service Request Dispatch Authorization - WO-00137912
Closed
Zone 1
WD Touchscreen not responding.
ADDITIONAL NOTES
POC is unavailable on Fridays. Parts shipping via UPS Next Day Air. For assistance, troubleshooting, or parts identification,
contact Veterinary Tech Service at 844-856-1232, option 1. Thank you!
Ship Exchanged Open 744550 002-10909-00 1.00000
Ship Exchanged Open 744550 002-10865-00 1.00000
Ship Exchanged Open 744550 002-10884-00 1.00000
12/22 MOwens Called and spoke to Michelle Hinks. She said they received the parts from Midmark and will have them ready for when the tech arrive onsite. She said Tues. 12/30 is the best day to schedule the repair visit based on her schedule for the holiday's. Confirmed the arrival between 8-9am.
12/18/25 lcoonrod
Your shipment
1ZE444250171384320
1 of 3 Piece Shipment
The delivery date will be provided as soon as possible.
Tracking Number:Ship To:Schreiber School Vet Medicine 1000 Gilbreth Pkwy Mullica Hill, NJ 080624458 USUPS Service:UPS NEXT DAY AIRPackage Weight:0.5 LBS
12/18/25 lcoornod
Your shipment
1ZE444250170066112
1 of 3 Piece Shipment
The delivery date will be provided as soon as possible.
Tracking Number:1ZE444250170066112Ship To:Schreiber School Vet Medicine 1000 Gilbreth Pkwy Mullica Hill, NJ 080624458 USUPS Service:UPS NEXT DAY AIRPackage Weight:2.8 LBS
12/17/2025jsells
Ship To Name: Schreiber School Vet Medicine
Ship To Address: 1000 Gilbreth Pkwy
Ship To City/State: Mullica Hill, NJ 08062-4458
Waybill (Tracking #): 1ZE444250171677102
Carrier: UPS-Air-Next Day Air
The following items have shipped from Midmark Corporation on: 17-DEC-2025
LINE NO: 1.1 QTY: 1 ITEM: 002-10884-00 SERIAL #: DESCRIPTION: M11-05X DISPLAY ASSEMBLY
LINE NO: 2.1 QTY: 1 ITEM: 002-10909-00 SERIAL #: DESCRIPTION: KIT, M9/M11-05X CONNECTIVITY MODULE
LINE NO: 3.1 QTY: 1 ITEM: 002-10865-00 SERIAL #: DESCRIPTION: KIT, 115V M9/M11-05X CONTROL PCB ASSY
12/16/25 SReich - There were three different options for vet services, sending an email.
🔧Work Performed
REPLACED DISPLAY ASSEMBLY, CONNECTIVITY MODULE, AND MAIN BOARD; TESTED GOOD; CYCLE TESTED GOOD
🔍Technician Findings
TOUCHSCREEN HARDWARE ISSUE
⚠️Problem Description
Zone 1
WD Touchscreen not responding.
ADDITIONAL NOTES
POC is unavailable on Fridays. Parts shipping via UPS Next Day Air. For assistance, troubleshooting, or parts identification,
contact Veterinary Tech Service at 844-856-1232, option 1. Thank you!
Ship Exchanged Open 744550 002-10909-00 1.00000
Ship Exchanged Open 744550 002-10865-00 1.00000
Ship Exchanged Open 744550 002-10884-00 1.00000
📄Description
Midmark Model M11 (Series) Self Contained Steam Sterilizer (Includes ALL M11 Models)
📋
Outbound to +18562566000
Completed Dec 22, 2025
Called and spoke to Michelle Hinks. She said they received the parts from Midmark and will have them ready for when the tech arrive onsite. She said Tues. 12/30 is the best day to schedule the repair visit based on her schedule for the holiday's. Confirmed the arrival between 8-9am.
📋
Outbound to +18562566000
Completed Dec 16, 2025
There were three different options for vet services, sending an email.
📅
WO-01326895 - Repair - M11 (Series) - Mullica Hill - Schreiber School Vet Medicine
Dec 30, 2025 8:30am – 12:00pm
Work Order: WO-01326895
Account: MIDMARK
Customer Case Number: SR 1509396 WO-00137912
Location: Schreiber School Vet Medicine
Address: 1000 Gilbreth Pkwy, Mullica Hill, NJ 08062-4458
Manufacturer: Midmark Corp
Model #: M11 (Series)
Serial #: V2831690
Contact Name: Michelle Hinks
Contact Phone: 1(856
PDF
SRA_WO-00137912_ver1
Dec 16, 2025
PDF
1326895x
Dec 30, 2025
Timeline
📞
Case Linked Dec 16, 1:38 PM
Case Number:00552147
Subject:Midmark Service Request Dispatch Authorization - WO-00137912