Zone 2
Dispatch Type Repair
PROBLEM SUMMARY
special billing/ NWD / Base very loud with weight on it - SRA Request
ADDITIONAL NOTES
If part(s) are identified after speaking with Midmark Tech Service, the Service Company Tech must contact Midmark Dispatch
at 937.688.9175 or dispatch@midmark.com with part number(s), quantities per serial number(s), current trip labor hour(s), and
estimated next trip labor hour(s). Midmark will send a revised estimate for customer approval, set a response deadline, and
advise the Service Company on how to proceed. For assistance, troubleshooting, or parts identification, contact Medical Tech
Service at 844-856-1230. Thank you!
Primary Delay7.4 days stuck in "Awaiting Parts - Customer"
⏱️
Total Delay10.5 business days over SLA thresholds
SLA vs Actual Time by Status
Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
0.0d / 0.5d SLA
Ready for Scheduling
7.4d / 1.0d SLA
Assigned
0.0d / 0.5d SLA
Awaiting Parts - Customer
7.4d
Scheduled
4.9d / 2.0d SLA
Tech On Site
0.4d / 1.0d SLA
Completed
0.3d / 1.0d SLA
Closed
2.0d / 1.0d SLA
Ready to Bill
1.3d / 1.0d SLA
💬 Activities, Notes & Communications
🔒Internal CSA Notes
2/27/26 RBerry- Updated delay code.
2-26 Mburris called Fernando set for 3-4 between 11am - 12:30pm
2/17/26 SReich
SCHEDULED DELIVERY DATE
Monday
2/23/26 by end of day
Order No: 755902
Customer PO No: 4010584736HTM
Customer: GE Healthcare
Service Request NO: 1532430
Ship To Name: Sutter Gould Med Foundation
Ship To Address: 1026 Lifestyle St
Ship To City/State: Manteca, CA 95337-9511
Waybill (Tracking #): 510299711150
Carrier: FEDX-Parcel-Ground
The following items have shipped from Midmark Corporation on: 17-FEB-2026
LINE NO: 1.1 QTY: 1 ITEM: 002-10093-00 SERIAL #: DESCRIPTION: KIT, RITTER BASE ACTUATOR ASS'Y
2/16/2026jsells
Hello, EMSAR,
Updating POC on this SR to Jacob Eccles. Part for this order mistakenly did not get submitted. It is now submitted under SO - 755902. Thanks!
2/5 KHardison - Left a vm regarding WO. Advised that a coordinator will call for scheduling, once shipping is confirmed for parts, once shipping is confirmed for parts
🔧Work Performed
Replaced Base Actuator Assembly and tested the base function on the chair. Loud squeaking noise was still present during operation. Contacted Midmark Technical Support to report findings. They advised that debris on the base guide rails can cause the loud squeaking noise. Cleaned the guide rails with rubbing alcohol as recommended. Tested the base function again and the loud squeaking noise is no longer present.
🔍Technician Findings
Arrived on site. Customer provided the Base Actuator Assembly that is to be replaced on the unit. Confirmed that the exam chair produces a very loud squeaking noise when activating the base function. The noise becomes louder when weight is applied to the chair.
⚠️Problem Description
Zone 2
Dispatch Type Repair
PROBLEM SUMMARY
special billing/ NWD / Base very loud with weight on it - SRA Request
ADDITIONAL NOTES
If part(s) are identified after speaking with Midmark Tech Service, the Service Company Tech must contact Midmark Dispatch
at 937.688.9175 or dispatch@midmark.com with part number(s), quantities per serial number(s), current trip labor hour(s), and
estimated next trip labor hour(s). Midmark will send a revised estimate for customer approval, set a response deadline, and
advise the Service Company on how to proceed. For assistance, troubleshooting, or parts identification, contact Medical Tech
Service at 844-856-1230. Thank you!
2-26 Mburris called Fernando set for 3-4 between 11am - 12:30pm
📋
Outbound to +12628759753
Completed Feb 5, 2026
Left a vm regarding WO. Advised that a coordinator will call for scheduling.
📅
WO-01349933 - Repair - 200 (Series) Tables and Chairs - Manteca - Sutter Gould Med Foundation
Mar 4, 2026 3:00pm – 5:00pm
Work Order: WO-01349933
Account: MIDMARK
Customer Case Number: SR 1532430
Location: Sutter Gould Med Foundation
Address: 1026 Lifestyle St, Manteca, CA 95337-9511
Manufacturer: Midmark
Model #: 200 (Series) Tables and Chairs
Serial #: V2760093
Contact Name: Fernando Candelario
Contact Phone: 1262875
PDF
00565455 SRA
Feb 5, 2026
PDF
00565455 SRA
Mar 4, 2026
Timeline
📞
Case Linked Feb 4, 4:09 PM
Case Number:00565455
Subject:Repair
Status:Closed
📋
▶
3
Work Order Created Feb 5, 2:27 PM
Work Order Created → Parts Added → Status: Ready for Scheduling