Work Order 360 View

Detailed work order timeline, KPIs, and analysis

← WO Overview

WO-01352260 ↗ ServiceMax

Conviva Care Solutions (Humana) • Virtual Tech - Field Repair • P3

📍 Conviva Southside — 5718 Spohn Dr, #100, Corpus Christi TX, 78414

Feb 17, 2026 → Feb 25, 2026

✅ Completed
P3 3 business days from creation
Target: Feb 20, 2026
🕐 Clock stopped: Completed (Feb 25)
✗ SLA Missed (5d late)
Dispatch 0.0d
Coordinators 7.3d
Field Work 0.0d
Billing 0.0d
✗ SLA Missed
Dispatch
0.0 days
Coordinators
7.3 days
Over SLA
Field Work
0.0 days
Billing
0.0 days
Created: Feb 17, 2026 Due: Feb 20, 2026 Completed: Feb 25, 2026 (4 days late)
📅
7.0 days Total Age
⏱️
7.0d in Scheduled Longest Stage
🔄
7 transitions Status Changes
⚠️
7.0d over Total Delay
📦
0 orders, 0 quotes Parts & Quotes
📝
3 lines Work Details
🏠
1 visit On-Site Trips
📋
Coordinator Scheduling

AI Analysis

Powered by OpenAI
Generating AI analysis...

Originating Case

Open in Salesforce →
🎫
Case #00545847
<no subject>
Closed
Name: Josie Garza Phone: 3612460325 Email: Jgarza@convivasolutions.com Notes: Fridge temp is not working Model: Accucold - ARS6PV Model Type: Refrigerator Asset ID: 13247175 Site: Conviva Care Solutions (Humana) - Conviva Southside<https://www.ebiotrack.com/sites.php?sid=25061> Serial #: Blank Derek S. Reynolds Virtual Tech Team derek.reynolds@emsar.com 888-841-5155 ext 2 Office: (937) 741-4833 [cid:2bd68684-a4fd-41da-b5dd-deb0e67e7dbd] EMSAR Confidentiality Notice: This electronic mail message, including any attachments, may contain information that is privileged, confidential, proprietary in nature, or otherwise private information that is protected by law from disclosure or subject to copyright and is intended only for the designated recipient. If you are not the designated recipient, you are hereby notified that any use, disclosure, distribution, reproduction, review, or copying is unauthorized and may be unlawful. If you have received this electronic message in error, please notify the sender immediately and delete the message completely from your computer system. Thank you.
Priority
Standard
Origin
Email
Reason
New Case
Contact
Josie Garza
Owner
Virtual Tech
Created
Nov 21, 2025
Work Orders from this Case (1)
WO-01352260 (current) Invoiced
Virtual Tech - Field Repair • Anthony Wirth
Created: Feb 17, 2026 • Closed: Feb 25, 2026
Completed with minor delays
Invoiced • 86 days old
🚨
Primary Delay 7.0 days stuck in "Scheduled"
⏱️
Total Delay 7.0 business days over SLA thresholds

SLA vs Actual Time by Status

Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
0.0d / 0.5d SLA
Ready for Scheduling
0.1d / 1.0d SLA
Assigned
0.2d / 0.5d SLA
Scheduled
7.0d / 2.0d SLA
Completed
0.0d / 1.0d SLA
Closed
3.0d / 1.0d SLA
Ready to Bill
0.0d / 1.0d SLA

💬 Activities, Notes & Communications

🔒 Internal CSA Notes

2/17 KKelch scheduled per logged email from Josie

2/17 KKelch sent Josie an email for scheduling

🔧 Work Performed
Upon arrival, I verified the customer's report of a temperature discrepancy and confirmed the unit was displaying a reading approximately 10°F higher than the actual internal temperature. After consulting the service manual, I determined the display was incorrectly configured to a secondary sensor/reference point. I recalibrated the control settings to the correct temperature input and performed a follow-up check to ensure the display now accurately matches the internal conditions. The unit is now operating within manufacturer specifications, and no further action is required.
🔍 Technician Findings
The temp of the unit is correct at 40 degrees but the unit thermometer is reading 9 to 10 degrees higher.
⚠️ Problem Description
Confirm Temps in Fridge and document results. Troubleshoot if out of spec. Notes: Fridge temp is not working Model: Accucold - ARS6PV Model Type: Refrigerator Asset ID: 13247175 Site: Conviva Care Solutions (Humana) - Conviva Southside Serial #: Blank https://www.ebiotrack.com/workorder.php?wo=71725

Timeline

📞
Case Linked Nov 21, 9:50 AM
Case Number: 00545847
Subject: <no subject>
Status: Closed
🚨 63.0 business days
📋
2 Work Order Created Feb 17, 8:31 AM
Work Order Created → Status: Ready for Scheduling
📅
Status: Ready for Scheduling by Derek Reynolds
From: Entered
To: Ready for Scheduling
Duration in Previous: 1m
👷
2 Technician Assigned Feb 17, 8:58 AM
Technician Assigned → Status: Assigned
👷
Status: Assigned by Kaitlyn Kelch
From: Ready for Scheduling
To: Assigned
Duration in Previous: 25m
🗓️
2 Status: Scheduled Feb 17, 10:43 AM
Status: Scheduled → Dispatch Scheduled
📅
Dispatch Scheduled by Kaitlyn Kelch
Scheduled For: 2026-02-25T18:00:00.000+0000
⚠️ 7.0 business days
✔️
2 Status: Completed Feb 25, 6:44 PM
Status: Completed → 2x Labor Added
⏱️
2x Labor Added
Type: Labor, Travel
Status: Open
Qty: 3, 186
⏱️
2 Labor Added Feb 25, 6:49 PM
Labor Added → Status: Closed
🏁
Status: Closed by Anthony Wirth
From: Completed
To: Closed
Duration in Previous: 8m
3.6 business days
📄
3 Status: Ready to Bill Mar 2, 2:17 PM
Status: Ready to Bill → Status: Invoice Pending → Invoice Created
📨
Status: Invoice Pending by Diane Patton
From: Ready to Bill, Invoice Pending
To: Invoice Pending, Invoiced
Duration in Previous: 1m, 0m
🧾
Invoice Created
Invoice Number: SM-255356

Bottlenecks

Scheduled
Duration: 7.0 business days (threshold: 2.0 business days)
Exceeded by 5.0 business days
Closed
Duration: 3.0 business days (threshold: 1.0 business days)
Exceeded by 2.0 business days

🔗 Related Artifacts

📞
Case 00545847
Closed

ℹ️ Work Order Details

Status
Invoiced
Priority
P3
Type
Virtual Tech - Field Repair
Branch
Edge
Technician
Anthony Wirth
Scheduled
Feb 25, 1:00 PM
Created
Feb 17, 8:31 AM
Invoice #
SM-255356

Work Details (3)

Name Type Status Qty Amount Date
WL-03120127 Labor Open 3 $357.00 Feb 25, 6:48 PM
WL-03120129 Travel Open 186 - Feb 25, 6:48 PM
WL-03120133 Labor Open 1.75 $208.25 Feb 25, 6:49 PM

Details