**Service needs to be completed in May 2026
PM/CAL needed on the following
Group 3 - Cost Center - US4214
Service needs completed in May 2026
Manufacturer EPPENDORF
Manufacturer Model # 5417R CENTRIFUGE BENCH TOP ENHANCED SYSTEM
SN 20576
Special Requirements-
Time: Low – 10sec; High 3 min
Temp: Low 0C; High 25C
Speed: Low 3,000; High 14,000
Manufacturer EPPENDORF
Manufacturer Model # 5427R CENTRIFUGE MICRO TYPICAL SYSTEM
SN 5409BN201223
Special Requirements-
Time: Low – 10sec; High 3 min
Temp: Low 0C; High 25C
Speed: Low 3,000; High 14,000
Manufacturer THERMO-FISHER
Manufacturer Model # Sorvall ST 16R CENTRIFUGE BENCH TOP TYPICAL SYSTEM
SN 42161876
Special Requirements Temp:
Low 0C; High 25C
Speed: Low 300; High 4,400
Total Delay111.9 business days over SLA thresholds
SLA vs Actual Time by Status
Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
0.0d / 0.5d SLA
Ready for Scheduling
10.2d / 1.0d SLA
Assigned
50.0d / 0.5d SLA
Scheduled
55.2d / 2.0d SLA
Reschedule
4.5d / 2.0d SLA
Tech On Site
0.9d / 1.0d SLA
Completed
1.2d / 1.0d SLA
Closed
2.5d / 1.0d SLA
L2 Review
3.0d
WO Correction Needed
0.1d
Invoice Pending
0.0d / 2.0d SLA
💬 Activities, Notes & Communications
🔒Internal CSA Notes
5.14.26 hshaw - chat Ashley for the quote.
5/4/2026 CRamen in a logged email from Ashley Daniels: Thank you for the follow-up! Please put us on the scheduled for this Friday.
4/28/2026 CRamen per LYoder in scheduling chat to re-schedule for a Midmark install near Duluth MN on 5/6. TR Cancelled
2/17/2026 CRamen in a logged email WO-01316159 scheduled with Ashley Daniels for Wednesday 5/6/2026 with tech arrival between 8-10am
2/16/2026 CRamen left a vm for a returned call to schedule for May PMs. Call and email logged on WO-01316159. Logged email
open availability Tuesday-Thursday (Monday or Friday needed for travel from or to Minneapolis MN) May with an arrival window between 8-10am.
🔧Work Performed
5/8/26
All lodging is on WO-01315969.
Added new speed tests (14000 RPM and 7000 RPM)
Added new temp test (4 o C and 22 o C)
Completed PM/Cal
Completed paperwork
Traveled from site
Closed WO
🔍Technician Findings
Added new speed tests (14000 RPM and 7000 RPM)
Added new temp test (4 o C and 22 o C)
unit needed 2026 PM/Cal
⚠️Problem Description
**Service needs to be completed in May 2026
1 of 3
PM/CAL needed on the following
Group 3 - Cost Center - US4214
Service needs completed in May 2026
Manufacturer EPPENDORF
Manufacturer Model # 5417R CENTRIFUGE BENCH TOP ENHANCED SYSTEM
SN 20576
Special Requirements-
Time: Low – 10sec; High 3 min
Temp: Low 0C; High 25C
Speed: Low 3,000; High 14,000
📄Description
Eppendorf Centrifuge Micro Refrigerated or Constant Temp 5417 Series (5417 C 5417 R)
📋
Inbound from +15127971696
Completed May 19, 2026
Ashley Daniels from Agilent called regarding instruments that were serviced on this WO last week. Customer is not happy and is requesting another tech visit. Sent chatter to tech/FOM and account manager.
📧
Email:RE: Scheduling Request for May 2026 CSA/ESMAR and Boehringer
Completed May 4, 2026
From: ashley.daniels@agilent.com
To: cramen@emsar.com
Cc: kaitlyn.kelch@emsar.com, aperry@emsar.com, lyoder@emsar.com, ronnie.salone@emsar.com
Hello Chuck, Thank you for the follow-up! Please put us on the scheduled for this Friday. All the best, Ashley Daniels Ashley Daniels, MHAEnterprise Program AdministratorAmericas Enterprise ServicesAgilent TechnologiesT: +1 512 797 1696| www.agilent.com From: Chuck Ramen <cramen@emsar.com> Sent: Monday, May 4, 2026 9:52 AMTo: DANIELS,ASH
📧
Email:RE: EMSAR Request for service at BI Vetmedica - St. Joseph (Email to schedule service)
Completed Feb 17, 2026
From: ashley.daniels@agilent.com
To: sukhpreet.singh@agilent.com, cramen@emsar.com, ronnie.salone@emsar.com
Hello Charles Can we please schedule this onsite date for Wednesday, May 6th? If not, please propose a few onsite dates. 20576 / WO-0131615942161876 / WO-01316162540712771 / WO-013159695401ZM704446 / WO-013245635409BN201223 / WO-013161605418BCH3197343 / WO-013245655428NM542208 / WO-01315971 Thank you, Ashley Daniels Ashley Daniels, MHAEnterprise Program AdministratorAmericas
📧
Email: EMSAR Request for service at BI Vetmedica - St. Joseph (Email to schedule service)
Completed Feb 16, 2026
To: sukhpreet.singh@agilent.com; ronnie.salone@emsar.com
CC:
BCC: cramen@emsar.com
Attachment: --none--
Subject: EMSAR Request for service at BI Vetmedica - St. Joseph (Email to schedule service)
Body:
Hi Preet Singh,
I hope you’re doing well. I’m reaching out to schedule a service appointment for **Service needs to be completed in May 2026
1 of 3
PM/CAL needed on the following
Group 3 - Cost Center - US4214
Service needs completed in May 2026
Manufacturer EPPENDORF
Manufacturer Model
📋
Outbound to +16097604621
Completed Feb 16, 2026
2/16/2026 CRamen left a vm for a returned call to schedule for May PMs. Call and email logged on WO-01316159
May 13, 2026 9:14am
/WO-01316159 Review complete, uploaded zip files to be mailed 5/14/26
May 13, 2026 9:43am
/WO-01316159 @Ronnie Salone We need to correct the speed calibration form. You noted the units were RPM, and the unit under test (UUT) (centrifuge) measured 14000 RPM, but listed the as found reference (your tool) as measuring RCF. We need to list the RPM value your tool measured in the 'As Found Reference' and compare that RPM value to the UUT. RCF depends on the size of the rotor and we don't use that with our tachometer.
May 13, 2026 11:31am
@Ronnie Salone do you have hotel expenses for this trip or other expenses? If so, please add it to WO. Thank you
May 14, 2026 12:50pm
@Ashley Perry do you happen to have the quote for case 00528855 Agilent PO# 9200954455?
May 19, 2026 4:13pm
@Lawrence Yoder @Ronnie Salone @Chris Bakkemo
Would you please reach out to Ashley Daniels at Agilent regarding instruments that were serviced on this WO last week. Customer is not happy and is requesting another tech visit. Ashley's phone # is 512.797.1696. She has also sent emails, FYI.
📅
WO-01316159 - Calibration - DD: 5/31/2026 - - SOL-100096 - St. Joseph - BI Vetmedica - St. Joseph
May 8, 2026 9:00am – 5:00pm
Work Order: WO-01316159
Account: AGILENT TECHNOLOGIES (CROSSLAB)
Customer Case Number:
Location: BI Vetmedica - St. Joseph
Address: 2621 North Belt Highway, St. Joseph, MO 64506
Manufacturer: Eppendorf
Model #: SOL-100096
Serial #: 20576
Contact Name: Preet Singh
Contact Phone: 609-760-4621
Contact